[. . . ] · Xpelair Technical Hotline:- +44 (0) 8709 000430 · Xpelair Technical Faxline:- +44 (0) 8709 000530 Head Office, UK Sales Office and Spares Applied Energy Products Ltd, Morley Way, Peterborough, PE2 9JJ England Telephone: Fax: Sales/Spares Hotline: Sales/Spares Faxline: +44 +44 +44 +44 (0) (0) (0) (0) 1733 1733 8709 8709 456789 310606 000420 000520 Part No. 567 2026 01 (Revision D) Xodus Toilet/Bathroom Fans XX100, XX100P & XX100T installation & operating instructions. Installing the fan These appliances are intended for connection to fixed wiring. [. . . ] If working above ground floor level, appropriate safety precautions must be observed. If window/panel mounting the fan you will also need XXGK4 Glass Kit. You will need a window pane between 3mm and 6mm thick (preferably 4mm). Do not install in glass 3mm thick if the window pane area is more than 0. 2 sq. If installing in sash windows you should mount the fan in the upper window. Secure the upper sash in the closed position and fit stops just below the level of the fan, to prevent damaging it when the sash is raised. · If ceiling mounting the fan, an XXCK4 Ceiling Kit is required and appropriate ancillaries for termination. If installing in a wall, ceiling or vent Mark the position of the back plate (fig A) 1. Hold the backplate so that the terminal block faces you in the top left hand corner and the lip points towards the hole. Mark on the wall/ceiling or vent shaft the positions of the three fixing holes in the back plate. Drill screw holes in these positions if necessary, and fit wall plugs if necessary. Mount the back plate (fig B) 1a. If installing in a vent, an XXVK4 Vent Kit is required. 1b. If installing in a ceiling, an XXCK4 Ceiling Kit and termination ancillaries are required. Feed the mains cable entry hole in the backplate to the terminals (Fig C). If wiring from above, leave the cable free to be fitted into labyrinth. Insert the lip of the back plate into the wall duct/ceiling or vent shaft as before. Fasten the back plate to the wall/ceiling or vent shaft using appropriate fasteners. · At least 110mm from the edges of the wall mounting surface to the centre of the hole. [. . . ] Connect the cable from the isolating switch to the electrical supply wiring. · For fixed wiring circuits the protective fuse for the appliance must not exceed 5A. Installing the isolating switch & cables All Fans · If wiring from above, cut out the cable entry slot marked on top of the front cover. · Fit the front cover by aligning it square to the duct and pushing it onto the backplate until the release catches snap into the slots on the front cover. [. . . ]